ATOS
Atos is a world leader in the production of components and systems for electrohydraulics.
ArticleCodeBrandAvail.
-
DLKZOR-TES-SF-NP-160-L71/BCIDLKZOR-TES-SF-NP-160-L71/BCIATOS
- Size NG10
- Nominal max pressure (bar) 315
- Max flow (lt/min) 130
- Type CLOSED LOOP SERVOPROPORTIONAL DIRECTIONAL VALVE
- Response time (ms) ≤ 15
- Ref. signal Volt
- Fail safe position NO
- Code DLKZOR-TES-SF-NP-160-L71/BCI
- Brand ATOS
-
Avail.
- Size NG10
- Nominal max pressure (bar) 315
- Max flow (lt/min) 130
- Type CLOSED LOOP SERVOPROPORTIONAL DIRECTIONAL VALVE
- Response time (ms) ≤ 15
- Ref. signal Volt
- Fail safe position NO
-
DLKZOR-TEB-SN-NP-160-L71/IY /PEDLKZOR-TEB-SN-NP-160-L71/IY /PEATOS
- Size NG10
- Nominal max pressure (bar) 315
- Max flow (lt/min) 130
- Type CLOSED LOOP SERVOPROPORTIONAL DIRECTIONAL VALVE
- Response time (ms) ≤ 15
- Ref. signal mA
- Fail safe position NO
- Code DLKZOR-TEB-SN-NP-160-L71/IY /PE
- Brand ATOS
-
Avail.
- Size NG10
- Nominal max pressure (bar) 315
- Max flow (lt/min) 130
- Type CLOSED LOOP SERVOPROPORTIONAL DIRECTIONAL VALVE
- Response time (ms) ≤ 15
- Ref. signal mA
- Fail safe position NO
-
DLKZOR-TEB-SN-NP-160-L31/FI 20/PEDLKZOR-TEB-SN-NP-160-L31/FI 20/PEATOS
- Size NG10
- Nominal max pressure (bar) 315
- Max flow (lt/min) 110
- Type CLOSED LOOP SERVOPROPORTIONAL DIRECTIONAL VALVE
- Response time (ms) ≤ 15
- Ref. signal mA
- Fail safe position NO
- Code DLKZOR-TEB-SN-NP-160-L31/FI 20/PE
- Brand ATOS
-
Avail.
- Size NG10
- Nominal max pressure (bar) 315
- Max flow (lt/min) 110
- Type CLOSED LOOP SERVOPROPORTIONAL DIRECTIONAL VALVE
- Response time (ms) ≤ 15
- Ref. signal mA
- Fail safe position NO
-
DLKZOR-TEB-SN-NP-140-T73DLKZOR-TEB-SN-NP-140-T73ATOS
- Size NG10
- Nominal max pressure (bar) 315
- Max flow (lt/min) 130
- Type CLOSED LOOP SERVOPROPORTIONAL DIRECTIONAL VALVE
- Response time (ms) ≤ 15
- Ref. signal Volt
- Fail safe position YES
- Code DLKZOR-TEB-SN-NP-140-T73
- Brand ATOS
-
Avail.
- Size NG10
- Nominal max pressure (bar) 315
- Max flow (lt/min) 130
- Type CLOSED LOOP SERVOPROPORTIONAL DIRECTIONAL VALVE
- Response time (ms) ≤ 15
- Ref. signal Volt
- Fail safe position YES
-
DLKZOR-TEB-SN-NP-140-L73/Y 11DLKZOR-TEB-SN-NP-140-L73/Y 11ATOS
- Size NG10
- Nominal max pressure (bar) 315
- Max flow (lt/min) 130
- Type CLOSED LOOP SERVOPROPORTIONAL DIRECTIONAL VALVE
- Response time (ms) ≤ 15
- Ref. signal Volt
- Fail safe position YES
- Code DLKZOR-TEB-SN-NP-140-L73/Y 11
- Brand ATOS
-
Avail.
- Size NG10
- Nominal max pressure (bar) 315
- Max flow (lt/min) 130
- Type CLOSED LOOP SERVOPROPORTIONAL DIRECTIONAL VALVE
- Response time (ms) ≤ 15
- Ref. signal Volt
- Fail safe position YES
-
DLKZOR-TEB-SN-NP-140-L71/FI /PEDLKZOR-TEB-SN-NP-140-L71/FI /PEATOS
- Size NG10
- Nominal max pressure (bar) 315
- Max flow (lt/min) 130
- Type CLOSED LOOP SERVOPROPORTIONAL DIRECTIONAL VALVE
- Response time (ms) ≤ 15
- Ref. signal mA
- Fail safe position YES
- Code DLKZOR-TEB-SN-NP-140-L71/FI /PE
- Brand ATOS
-
Avail.
- Size NG10
- Nominal max pressure (bar) 315
- Max flow (lt/min) 130
- Type CLOSED LOOP SERVOPROPORTIONAL DIRECTIONAL VALVE
- Response time (ms) ≤ 15
- Ref. signal mA
- Fail safe position YES
-
DLKZOR-TEB-SN-NP-140-L31/I 11DLKZOR-TEB-SN-NP-140-L31/I 11ATOS
- Size NG10
- Nominal max pressure (bar) 315
- Max flow (lt/min) 110
- Type CLOSED LOOP SERVOPROPORTIONAL DIRECTIONAL VALVE
- Response time (ms) ≤ 15
- Ref. signal mA
- Fail safe position YES
- Code DLKZOR-TEB-SN-NP-140-L31/I 11
- Brand ATOS
-
Avail.
- Size NG10
- Nominal max pressure (bar) 315
- Max flow (lt/min) 110
- Type CLOSED LOOP SERVOPROPORTIONAL DIRECTIONAL VALVE
- Response time (ms) ≤ 15
- Ref. signal mA
- Fail safe position YES
-
DLKZOR-TEB-SN-NP-140-D73/IQ 11DLKZOR-TEB-SN-NP-140-D73/IQ 11ATOS
- Size NG10
- Nominal max pressure (bar) 315
- Max flow (lt/min) 130
- Type CLOSED LOOP SERVOPROPORTIONAL DIRECTIONAL VALVE
- Response time (ms) ≤ 15
- Ref. signal mA
- Fail safe position YES
- Code DLKZOR-TEB-SN-NP-140-D73/IQ 11
- Brand ATOS
-
Avail.
- Size NG10
- Nominal max pressure (bar) 315
- Max flow (lt/min) 130
- Type CLOSED LOOP SERVOPROPORTIONAL DIRECTIONAL VALVE
- Response time (ms) ≤ 15
- Ref. signal mA
- Fail safe position YES
-
DLKZOR-TEB-SN-NP-140-D73DLKZOR-TEB-SN-NP-140-D73ATOS
- Size NG10
- Nominal max pressure (bar) 315
- Max flow (lt/min) 130
- Type CLOSED LOOP SERVOPROPORTIONAL DIRECTIONAL VALVE
- Response time (ms) ≤ 15
- Ref. signal Volt
- Fail safe position YES
- Code DLKZOR-TEB-SN-NP-140-D73
- Brand ATOS
-
Avail.
- Size NG10
- Nominal max pressure (bar) 315
- Max flow (lt/min) 130
- Type CLOSED LOOP SERVOPROPORTIONAL DIRECTIONAL VALVE
- Response time (ms) ≤ 15
- Ref. signal Volt
- Fail safe position YES
-
DLKZA-TES-SN-NP-140-L73/M/I 21 /PEDLKZA-TES-SN-NP-140-L73/M/I 21 /PEATOS
- Size NG10
- Nominal max pressure (bar) 315
- Max flow (lt/min) 100
- Type EX-PROOF SERVOPROPORTIONAL DIRECTIONAL VALVES
- Response time (ms) ≤ 20
- Ref. signal mA
- Fail safe position YES
- Code DLKZA-TES-SN-NP-140-L73/M/I 21 /PE
- Brand ATOS
-
Avail.
- Size NG10
- Nominal max pressure (bar) 315
- Max flow (lt/min) 100
- Type EX-PROOF SERVOPROPORTIONAL DIRECTIONAL VALVES
- Response time (ms) ≤ 20
- Ref. signal mA
- Fail safe position YES
-
DLKZA-TES-SN-NP-140-L71/M/I 21DLKZA-TES-SN-NP-140-L71/M/I 21ATOS
- Size NG10
- Nominal max pressure (bar) 315
- Max flow (lt/min) 100
- Type EX-PROOF SERVOPROPORTIONAL DIRECTIONAL VALVES
- Response time (ms) ≤ 20
- Ref. signal mA
- Fail safe position YES
- Code DLKZA-TES-SN-NP-140-L71/M/I 21
- Brand ATOS
-
Avail.
- Size NG10
- Nominal max pressure (bar) 315
- Max flow (lt/min) 100
- Type EX-PROOF SERVOPROPORTIONAL DIRECTIONAL VALVES
- Response time (ms) ≤ 20
- Ref. signal mA
- Fail safe position YES
-
DLKZA-TES-SN-NP-140-L31/MDLKZA-TES-SN-NP-140-L31/MATOS
- Size NG10
- Nominal max pressure (bar) 315
- Max flow (lt/min) 70
- Type EX-PROOF SERVOPROPORTIONAL DIRECTIONAL VALVES
- Response time (ms) ≤ 20
- Ref. signal Volt
- Fail safe position YES
- Code DLKZA-TES-SN-NP-140-L31/M
- Brand ATOS
-
Avail.
- Size NG10
- Nominal max pressure (bar) 315
- Max flow (lt/min) 70
- Type EX-PROOF SERVOPROPORTIONAL DIRECTIONAL VALVES
- Response time (ms) ≤ 20
- Ref. signal Volt
- Fail safe position YES
-
DLKZA-T-160-L71/GK/BCDLKZA-T-160-L71/GK/BCATOS
- Size NG10
- Nominal max pressure (bar) 315
- Max flow (lt/min) 100
- Type EX-PROOF SERVOPROPORTIONAL DIRECTIONAL VALVES
- Response time (ms) ≤ 13
- Ref. signal Volt
- Fail safe position NO
- Code DLKZA-T-160-L71/GK/BC
- Brand ATOS
-
Avail.
- Size NG10
- Nominal max pressure (bar) 315
- Max flow (lt/min) 100
- Type EX-PROOF SERVOPROPORTIONAL DIRECTIONAL VALVES
- Response time (ms) ≤ 13
- Ref. signal Volt
- Fail safe position NO
-
DLKZA-T-140-V73/MDLKZA-T-140-V73/MATOS
- Size NG10
- Nominal max pressure (bar) 315
- Max flow (lt/min) 100
- Type EX-PROOF SERVOPROPORTIONAL DIRECTIONAL VALVES
- Response time (ms) ≤ 13
- Ref. signal Volt
- Fail safe position YES
- Code DLKZA-T-140-V73/M
- Brand ATOS
-
Avail.
- Size NG10
- Nominal max pressure (bar) 315
- Max flow (lt/min) 100
- Type EX-PROOF SERVOPROPORTIONAL DIRECTIONAL VALVES
- Response time (ms) ≤ 13
- Ref. signal Volt
- Fail safe position YES
-
DLKZA-T-140-L71/GKDLKZA-T-140-L71/GKATOS
- Size NG10
- Nominal max pressure (bar) 315
- Max flow (lt/min) 100
- Type EX-PROOF SERVOPROPORTIONAL DIRECTIONAL VALVES
- Response time (ms) ≤ 13
- Ref. signal Volt
- Fail safe position YES
- Code DLKZA-T-140-L71/GK
- Brand ATOS
-
Avail.
- Size NG10
- Nominal max pressure (bar) 315
- Max flow (lt/min) 100
- Type EX-PROOF SERVOPROPORTIONAL DIRECTIONAL VALVES
- Response time (ms) ≤ 13
- Ref. signal Volt
- Fail safe position YES
-
DLKZA-T-140-L31/NPT/C 44 /PEDLKZA-T-140-L31/NPT/C 44 /PEATOS
- Size NG10
- Nominal max pressure (bar) 315
- Max flow (lt/min) 70
- Type EX-PROOF SERVOPROPORTIONAL DIRECTIONAL VALVES
- Response time (ms) ≤ 13
- Ref. signal Volt
- Fail safe position YES
- Code DLKZA-T-140-L31/NPT/C 44 /PE
- Brand ATOS
-
Avail.
- Size NG10
- Nominal max pressure (bar) 315
- Max flow (lt/min) 70
- Type EX-PROOF SERVOPROPORTIONAL DIRECTIONAL VALVES
- Response time (ms) ≤ 13
- Ref. signal Volt
- Fail safe position YES
-
DLKZA-T-140-L31/NPT/C 43 /PEDLKZA-T-140-L31/NPT/C 43 /PEATOS
- Size NG10
- Nominal max pressure (bar) 315
- Max flow (lt/min) 70
- Type EX-PROOF SERVOPROPORTIONAL DIRECTIONAL VALVES
- Response time (ms) ≤ 13
- Ref. signal Volt
- Fail safe position YES
- Code DLKZA-T-140-L31/NPT/C 43 /PE
- Brand ATOS
-
Avail.
- Size NG10
- Nominal max pressure (bar) 315
- Max flow (lt/min) 70
- Type EX-PROOF SERVOPROPORTIONAL DIRECTIONAL VALVES
- Response time (ms) ≤ 13
- Ref. signal Volt
- Fail safe position YES
-
DLKZA-T-140-L31/NPT/C 43DLKZA-T-140-L31/NPT/C 43ATOS
- Size NG10
- Nominal max pressure (bar) 315
- Max flow (lt/min) 70
- Type EX-PROOF SERVOPROPORTIONAL DIRECTIONAL VALVES
- Response time (ms) ≤ 13
- Ref. signal Volt
- Fail safe position YES
- Code DLKZA-T-140-L31/NPT/C 43
- Brand ATOS
-
Avail.
- Size NG10
- Nominal max pressure (bar) 315
- Max flow (lt/min) 70
- Type EX-PROOF SERVOPROPORTIONAL DIRECTIONAL VALVES
- Response time (ms) ≤ 13
- Ref. signal Volt
- Fail safe position YES
-
DLHZO-TES-SP-NP-040-L01/CI 50DLHZO-TES-SP-NP-040-L01/CI 50ATOS
- Size NG06
- Nominal max pressure (bar) 350
- Max flow (lt/min) 8
- Type CLOSED LOOP SERVOPROPORTIONAL DIRECTIONAL VALVE
- Response time (ms) ≤ 10
- Ref. signal mA
- Fail safe position YES
- Code DLHZO-TES-SP-NP-040-L01/CI 50
- Brand ATOS
-
Avail.
- Size NG06
- Nominal max pressure (bar) 350
- Max flow (lt/min) 8
- Type CLOSED LOOP SERVOPROPORTIONAL DIRECTIONAL VALVE
- Response time (ms) ≤ 10
- Ref. signal mA
- Fail safe position YES
-
DLHZO-TES-SP-BP-040-L33/CIDLHZO-TES-SP-BP-040-L33/CIATOS
- Size NG06
- Nominal max pressure (bar) 350
- Max flow (lt/min) 30
- Type CLOSED LOOP SERVOPROPORTIONAL DIRECTIONAL VALVE
- Response time (ms) ≤ 10
- Ref. signal mA
- Fail safe position YES
- Code DLHZO-TES-SP-BP-040-L33/CI
- Brand ATOS
-
Avail.
- Size NG06
- Nominal max pressure (bar) 350
- Max flow (lt/min) 30
- Type CLOSED LOOP SERVOPROPORTIONAL DIRECTIONAL VALVE
- Response time (ms) ≤ 10
- Ref. signal mA
- Fail safe position YES